Valvetop-D Series
DXS | Characteristic | Download |
|
-Zone 0 Intrinsically Safe -Zone 1 Flameproof/ExplosionProof -Stainless Steel Enclosure -GO® Switch Leverless Limit Switches -FOUNDATION Fieldbus -AS-Interface -DeviceNet-4-20mA Position Transmitter-HART Protocol -Proximity Switches -Custom builds available |
DXP | Characteristic | Download |
|
-Tropicalized AluminumEnclosure -GO Switch Leverless LimitSwitches -FOUNDATION Fieldbus -AS-Interface -DeviceNet -4-20mA Position Transmitter -HART Protocol-Proximity Switches -Mechanical Switches -Custom builds available |
|
DXR | Characteristic | Download |
|
-Composite Resin Enclosure -GO® Switch Leverless LimitSwitches -FOUNDATION Fieldbus -AS-Interface -DeviceNet -4-20mA Position TransmitterHART Protocol -Proximity Switches-Mechanical Switches |
|
Valvetop-T Series
TVA | Characteristic | Specifications | Download |
-IncredibleValue!Broadrange offeatures andoptions,AS-Interface,multiple sensor,and integral solenoid valveoptions -Direct mount capability eliminates expensive mounting brackets -Easiest camadjustment inthe industry |
-Direct-Mount Composite Resin -Non-Incendive/ -Class 1 Division 2 Groups A-D -Ex ia llC T4 112G |
TXP | Characteristic | Specifications | Download |
-Rugged aluminum enclosure mounts directly to NAMUR valve actuators -Color-coded twist-set cams provide the easiest sensor adjustment in the industry -AS-interface and multiple sensor options -Highly visible, low profile position indicator -Optional integral 1.0 Cv solenoid valve for actuator control -ATEX… flame proof, non-incendive, and general purpose certifications (Zone 1, Div. 2, Ordinary Location) |
-Direct-Mount Aluminum -Flameproof/Explosion Proof/Intrinsically Safe -Class I Division 2 Groups A-D -Ex ia IIC T4 Tamb -50°C II2G -Ex d IIB T6 Tamb -50°C II2G -Ex d IIC T4 Tamb -50°C to 80°C (Flat top) -Ex d IIB+H2 T6 Tamb |
TXS | Characteristic | Specifications | Download |
-Rugged aluminum enclosure mounts directly to NAMUR valve actuators -Color-coded twist-set cams provide the easiest sensor adjustment in the industry -AS-interface and multiple sensor options -Highly visible, low profile position indicator -Optional integral 1.0 Cv solenoid valve for actuator control -ATEX… flame proof, non-incendive, and general purpose certifications (Zone 1, Div. 2, Ordinary Location) |
-Direct-Mount Stainless Steel -Flameproof/Explosion Proof/Intrinsically Safe -Class I Division 2 Groups A-D -Ex ia IIC T4 Tamb -Ex d IIB T6 Tamb -Ex d IIC T4 Tamb -Ex d IIB+H2 T6 Tamb |